| CWJS |
WINDING OPERATING VOLTAGE |
700.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 300.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 200.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 100.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 800.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 600.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 500.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 400.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY AND 900.00 AC MAJOR WET SINGLE COMPONENT 1ST SECONDARY |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
7.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 2.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 3.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 8.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 1.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 4.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 9.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
47 SOLDER STUD |
| CRMJ |
WINDING POWER RATING |
3.66 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| ADAU |
BODY HEIGHT |
4.266 INCHES MINIMUM AND 4.296 INCHES MAXIMUM |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
600.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ADAT |
BODY WIDTH |
3.141 INCHES MINIMUM AND 3.171 INCHES MAXIMUM |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
600.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 122.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 102.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 107.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 112.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 97.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CBME |
CUBIC MEASURE (NON-CORE) |
46.16 CUBIC INCHES |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRMJ |
WINDING POWER RATING |
5.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CRMJ |
WINDING POWER RATING |
0.54 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
3.360 INCHES MINIMUM AND 3.390 INCHES MAXIMUM |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 80.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 40.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 30.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 60.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 20.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 70.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 90.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 50.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT ALL SECONDARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.485 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.515 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
33.3 MILLIAMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |