| CRMJ |
WINDING POWER RATING |
189.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
25.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| FEAT |
SPECIAL FEATURES |
3 PRIMARY WINDINGS; 5 SECONDARY WINDINGS; 1 CONTROL WINDING |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CRGS |
DC RESISTANCE RATING IN OHMS |
1.000 SINGLE COMPONENT 3RD SECONDARY |
| CBME |
CUBIC MEASURE (NON-CORE) |
37.10 CUBIC INCHES |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| CRGS |
DC RESISTANCE RATING IN OHMS |
5340.000 SINGLE COMPONENT 3RD PRIMARY |
| BPLC |
WINDING FUNCTION AND QUANTITY |
3 PRIMARY SINGLE COMPONENT AND 1 CONTROL SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
| AEHZ |
MAXIMUM OPERATING TEMP |
105.0 DEG CELSIUS |
| ABKW |
OVERALL HEIGHT |
2.937 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
630.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE CONTROL |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
110.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT ALL PRIMARY AND 120.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT ALL PRIMARY |
| CRGS |
DC RESISTANCE RATING IN OHMS |
6.600 SINGLE COMPONENT 2ND PRIMARY |
| CHTZ |
SATURATION CURRENT RATING |
300.0 MILLIAMPERES |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.290 SINGLE COMPONENT 1ST SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
25.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CRGS |
DC RESISTANCE RATING IN OHMS |
1.200 SINGLE COMPONENT 4TH SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.735 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.765 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
6.094 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.124 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRGS |
DC RESISTANCE RATING IN OHMS |
120.000 SINGLE COMPONENT SINGLE CONTROL |
| CQJX |
NOMINAL THREAD SIZE |
0.112 INCHES SINGLE GROUP |
| CRGS |
DC RESISTANCE RATING IN OHMS |
3.000 SINGLE COMPONENT 1ST PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
25.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
24 WIRE LOOP |
| CWJS |
WINDING OPERATING VOLTAGE |
5.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| ABMK |
OVERALL WIDTH |
1.900 INCHES MAXIMUM |
| CRGS |
DC RESISTANCE RATING IN OHMS |
1.000 SINGLE COMPONENT 2ND SECONDARY |
| ABHP |
OVERALL LENGTH |
6.650 INCHES MAXIMUM |