| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ADAU |
BODY HEIGHT |
4.750 INCHES MINIMUM AND 4.875 INCHES MAXIMUM |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
13 SOLDER STUD |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.110 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.140 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB |
FREQUENCY RATING |
54.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ADAT |
BODY WIDTH |
2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
4.09 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
650.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
| ADAQ |
BODY LENGTH |
3.437 INCHES MINIMUM AND 3.562 INCHES MAXIMUM |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| CBME |
CUBIC MEASURE (NON-CORE) |
53.17 CUBIC INCHES |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| CRMJ |
WINDING POWER RATING |
12.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
710.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CRMJ |
WINDING POWER RATING |
24.85 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
35.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
126.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 132.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.580 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.610 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |