| ACZB |
FREQUENCY RATING |
48.0 HERTZ MINIMUM SINGLE COMPONENT AND 62.0 HERTZ MAXIMUM SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 210.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 250.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
2.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| ADAQ |
BODY LENGTH |
6.995 INCHES MINIMUM AND 7.005 INCHES MAXIMUM |
| CBME |
CUBIC MEASURE (NON-CORE) |
220.3 CUBIC INCHES |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 5TH SECONDARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
24 TAB, SOLDER LUG AND 3 STANDOFF, SOLDER LUG |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 6TH SECONDARY |
| ADAT |
BODY WIDTH |
6.120 INCHES MINIMUM AND 6.130 INCHES MAXIMUM |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
225.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
1.25 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
500.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| FEAT |
SPECIAL FEATURES |
1PRIMARY WINDING; 6SECONDARY WINDINGS |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
| ADAU |
BODY HEIGHT |
5.120 INCHES MINIMUM AND 5.130 INCHES MAXIMUM |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |