| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
58.3 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.907 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.000 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 116.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
225.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
116.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 213.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
225.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ADAU |
BODY HEIGHT |
2.500 INCHES MINIMUM AND 2.532 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 WIRE LEAD |
| CWJS |
WINDING OPERATING VOLTAGE |
80.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAT |
BODY WIDTH |
1.906 INCHES MINIMUM AND 1.984 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |