| ACYW |
IMPEDANCE RATING IN OHMS |
50.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| AXGY |
MOUNTING METHOD |
FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
| ACZH |
PRIMARY TO SECONDARY TURN RATIO |
1 TO 1 TO 1 TO 1 SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ADAU |
BODY HEIGHT |
2.438 INCHES NOMINAL |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
140.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| ACYV |
INDUCTANCE RATING |
800.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| ABTD |
MOUNTING SLOT WIDTH |
0.156 INCHES NOMINAL SINGLE GROUP |
| ADAQ |
BODY LENGTH |
2.062 INCHES NOMINAL |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRGS |
DC RESISTANCE RATING IN OHMS |
2.000 SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
140.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
5.5 KILOVOLTS SINGLE COMPONENT ALL SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 TAB, SOLDER LUG |
| ACYW |
IMPEDANCE RATING IN OHMS |
1.05 NOMINAL SINGLE COMPONENT ALL SECONDARY |
| ADAT |
BODY WIDTH |
1.625 INCHES NOMINAL |
| CRGS |
DC RESISTANCE RATING IN OHMS |
2.000 SINGLE COMPONENT 2ND SECONDARY |
| ACZN |
PULSE REPETITION RATE |
1.6 KILOHERTZ SINGLE COMPONENT |
| ACZL |
PULSE RISE TIME IN MICROSECONDS (NON-CORE) |
0.060 SINGLE COMPONENT |
| ACZK |
PULSE DURATION IN MICROSECONDS (NON-CORE) |
0.400 SINGLE COMPONENT |
| CBME |
CUBIC MEASURE (NON-CORE) |
8.2 CUBIC INCHES |
| AKNA |
INCLOSURE TYPE |
OPEN |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.250 SINGLE COMPONENT SINGLE PRIMARY |