| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
6.3 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
1.2 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.682 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.692 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ADAU |
BODY HEIGHT |
4.625 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
13 SOLDER STUD |
| FEAT |
SPECIAL FEATURES |
1 PRIMARY; 5 SECONDARY WINDINGS |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
16.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| ADAT |
BODY WIDTH |
3.812 INCHES MAXIMUM |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ABKW |
OVERALL HEIGHT |
5.125 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
4.437 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
850.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
5.00 AMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.307 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.317 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
80.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 70.0 HERTZ MAXIMUM SINGLE COMPONENT |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |