| ACYW |
IMPEDANCE RATING IN OHMS |
50.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 TAB, SOLDER LUG |
| ACYW |
IMPEDANCE RATING IN OHMS |
1000.0 NOMINAL SINGLE COMPONENT ALL SECONDARY |
| ACZN |
PULSE REPETITION RATE |
400.0 HERTZ SINGLE COMPONENT |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
10.0 VOLTS SINGLE COMPONENT ALL SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| ADAQ |
BODY LENGTH |
3.000 INCHES NOMINAL |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ACZM |
PULSE DECAY TIME IN MICROSECONDS (NON-CORE) |
1.200 SINGLE COMPONENT |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| ACZK |
PULSE DURATION IN MICROSECONDS (NON-CORE) |
2.200 SINGLE COMPONENT |
| AEHZ |
MAXIMUM OPERATING TEMP |
130.0 DEG CELSIUS |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| ABKW |
OVERALL HEIGHT |
3.500 INCHES MAXIMUM |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABHP |
OVERALL LENGTH |
3.375 INCHES MAXIMUM |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ACZL |
PULSE RISE TIME IN MICROSECONDS (NON-CORE) |
0.060 SINGLE COMPONENT |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| ADAT |
BODY WIDTH |
2.000 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
2.750 INCHES MAXIMUM |
| CRGS |
DC RESISTANCE RATING IN OHMS |
3.500 SINGLE COMPONENT ALL SECONDARY |
| ADAU |
BODY HEIGHT |
3.250 INCHES MAXIMUM |