| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRGS |
DC RESISTANCE RATING IN OHMS |
1.000 SINGLE COMPONENT 2ND WINDING |
| AKDX |
WINDING QUANTITY |
4 SINGLE COMPONENT |
| BKPL |
RATING METHOD |
ELECTRICAL SINGLE COMPONENT ALL WINDING |
| ACYV |
INDUCTANCE RATING |
33.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 3RD WINDING |
| ACYV |
INDUCTANCE RATING |
11.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 2ND WINDING |
| CRGS |
DC RESISTANCE RATING IN OHMS |
1.000 SINGLE COMPONENT 3RD WINDING |
| ADAQ |
BODY LENGTH |
2.344 INCHES MAXIMUM |
| ACYV |
INDUCTANCE RATING |
160.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 4TH WINDING |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CRBZ |
WINDING OPERATING CURRENT |
100.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH WINDING |
| ADAT |
BODY WIDTH |
2.094 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT |
3.562 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 TAB, SOLDER LUG |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| ACYF |
INDUCTANCE TYPE |
FIXED |
| AEHZ |
MAXIMUM OPERATING TEMP |
65.0 DEG CELSIUS |
| ADAU |
BODY HEIGHT |
3.125 INCHES MAXIMUM |
| ACYV |
INDUCTANCE RATING |
4.50 MILLIHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.500 SINGLE COMPONENT 1ST WINDING |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST WINDING |
| CRBZ |
WINDING OPERATING CURRENT |
300.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND WINDING |
| CRBZ |
WINDING OPERATING CURRENT |
350.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD WINDING |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |
| ACZB |
FREQUENCY RATING |
120.0 HERTZ NOMINAL SINGLE COMPONENT |
| CRGS |
DC RESISTANCE RATING IN OHMS |
3.000 SINGLE COMPONENT 4TH WINDING |