| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
12.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
12.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| CBME |
CUBIC MEASURE (NON-CORE) |
193.2 CUBIC INCHES |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| ADAQ |
BODY LENGTH |
7.000 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
22.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| AEHZ |
MAXIMUM OPERATING TEMP |
70.0 DEG CELSIUS |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CRBZ |
WINDING OPERATING CURRENT |
5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| CRBZ |
WINDING OPERATING CURRENT |
5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
24 TURRET |
| ADAU |
BODY HEIGHT |
5.812 INCHES MAXIMUM |
| CBBL |
FEATURES PROVIDED |
W/RECTIFIER |
| CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| ADAT |
BODY WIDTH |
4.750 INCHES MAXIMUM |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
DELTA-DELTA |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
6.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
3.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
22.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| FEAT |
SPECIAL FEATURES |
1PRIMARY WINDING; 7SECONDARY WINDINGS |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
HUMIDITY RESISTANT AND VIBRATION RESISTANT |