| AAJD |
THREAD CLASS (NON-CORE) |
2B ALL GROUPINGS |
| ADAT |
BODY WIDTH |
4.500 INCHES NOMINAL |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ADAU |
BODY HEIGHT |
5.000 INCHES NOMINAL |
| CWJS |
WINDING OPERATING VOLTAGE |
4.50 DC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 18.00 DC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 9.00 DC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 18.00 DC POUNDS PER HOUR DRY SINGLE COMPONENT 4TH SECONDARY AND 22.00 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
| ACZB |
FREQUENCY RATING |
47.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
16 WIRE LEAD |
| CRBZ |
WINDING OPERATING CURRENT |
1.3 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND ALL GROUPINGS |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
| FEAT |
SPECIAL FEATURES |
IPRIMARY; 5 SECONDARY WINDINGS |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
| AXGY |
MOUNTING METHOD |
THREADED HOLE ALL GROUPINGS |
| CRBZ |
WINDING OPERATING CURRENT |
3.8 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
6.50 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
| CBME |
CUBIC MEASURE (NON-CORE) |
126.7 CUBIC INCHES |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES ALL GROUPINGS |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNF ALL GROUPINGS |
| CWJS |
WINDING OPERATING VOLTAGE |
22.00 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 4TH SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
11.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
11.00 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
8 ALL GROUPINGS |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| CBBL |
FEATURES PROVIDED |
COLOR CODED LEAD |
| ADAQ |
BODY LENGTH |
5.630 INCHES NOMINAL |
| CRBZ |
WINDING OPERATING CURRENT |
1.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |