| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
1.3 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
1.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 TURRET |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
100.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| AEHZ |
MAXIMUM OPERATING TEMP |
105.0 DEG CELSIUS |
| CRMJ |
WINDING POWER RATING |
1.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
18.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ADAU |
BODY HEIGHT |
2.187 INCHES MINIMUM AND 2.312 INCHES MAXIMUM |
| ACZF |
MAXIMUM TRANSFORMER POWER RATING |
40.0 VOLT-AMPERE SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
2.937 INCHES MINIMUM AND 3.125 INCHES MAXIMUM |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
22.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
109.25 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.75 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CRMJ |
WINDING POWER RATING |
36.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ADAT |
BODY WIDTH |
1.937 INCHES MINIMUM AND 2.062 INCHES MAXIMUM |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
18.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
100.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL SINGLE COMPONENT |