5950-01-055-3984 ( C15899 , 25P223188-01 , PEI 8157 , TTI-11563 )

NSN Information
NSN FSC NIIN Item Name INC
5950-01-055-3984 5950 010553984 TRANSFORMER,POWER 3249
NSN Features
MRC Parameter Characteristics
ABHP OVERALL LENGTH 1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM
ABTB MOUNTING HOLE DIAMETER 0.177 INCHES MINIMUM SINGLE GROUP AND 0.197 INCHES MAXIMUM SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
ACZD TRANSFORMER WINDING CONNECTION TYPE WYE-WYE
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 689.6 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 13 EYELET
CRBZ WINDING OPERATING CURRENT 4.03 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY
CRBZ WINDING OPERATING CURRENT 541.9 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAU BODY HEIGHT 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION VIBRATION RESISTANT
CRMJ WINDING POWER RATING 25.0 WATTS SINGLE COMPONENT 3RD SECONDARY
CBME CUBIC MEASURE (NON-CORE) 5.0 CUBIC INCHES
CWJS WINDING OPERATING VOLTAGE 20.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AKNA INCLOSURE TYPE HERMETICALLY SEALED
CWJS WINDING OPERATING VOLTAGE 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
AXGY MOUNTING METHOD BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 20.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CRMJ WINDING POWER RATING 11.0 WATTS SINGLE COMPONENT 2ND SECONDARY
ADAT BODY WIDTH 1.615 INCHES MINIMUM AND 1.635 INCHES MAXIMUM
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
CRMJ WINDING POWER RATING 14.0 WATTS SINGLE COMPONENT 1ST SECONDARY
AEHZ MAXIMUM OPERATING TEMP 170.0 DEG CELSIUS
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.215 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.235 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 6.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
C15899 72149 A 2 5 5 ZZ
25P223188-01 98738 E 2 3 A TX
PEI 8157 13483 A 2 5 5 ZZ
TTI-11563 96253 F 9 5 A TX
Manufacturers
Part SKU Cage Manufacturer Type Status
C15899 72149 ELECTRONIC TRANSFORMER CORP. A A
25P223188-01 98738 HERLEY CHICAGO A E
PEI 8157 13483 PRECISION ELECTRONICS INC. A A
TTI-11563 96253 TRANSFORMER TECHNICIANS INC A F
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 1 02/04/1 P 3249
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS I
DN 9B----- N
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Z 0 EA 0 U D
DN SMS Z 0 EA 0 U 9B----- N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
063420 X 35355 P 595 Z 9 A H Z TRANSFORMERS NOI LESS THAN 25 LBS