5950-01-057-5040 ( 984852-1C , PA60087-1 , 18145 , 12846 )

NSN Information
NSN FSC NIIN Item Name INC
5950-01-057-5040 5950 010575040 TRANSFORMER,POWER 3249
NSN Features
MRC Parameter Characteristics
CRMJ WINDING POWER RATING 9.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 3RD SECONDARY
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SIX PHASE SINGLE COMPONENT
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 17.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
CRMJ WINDING POWER RATING 90.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZF MAXIMUM TRANSFORMER POWER RATING 352.3 VOLT-AMPERE SINGLE COMPONENT
AEHZ MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS
ACZB FREQUENCY RATING 480.0 HERTZ MAXIMUM SINGLE COMPONENT
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 300.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 18 TURRET
CRBZ WINDING OPERATING CURRENT 6.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
CRMJ WINDING POWER RATING 253.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 6.500 POUNDS
CWJS WINDING OPERATING VOLTAGE 26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ADAQ BODY LENGTH 4.800 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 24.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 198.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ADAT BODY WIDTH 2.500 INCHES MAXIMUM
CQJX NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
ADAU BODY HEIGHT 3.440 INCHES NOMINAL
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
984852-1C 82577 A 2 5 A TX
PA60087-1 82577 A 2 5 5 TX
18145 72964 A 2 5 5 TX
12846 53854 A 2 3 2 9Z
Manufacturers
Part SKU Cage Manufacturer Type Status
984852-1C 82577 RAYTHEON COMPANY F A
PA60087-1 82577 RAYTHEON COMPANY F A
18145 72964 ROBERT M HADLEY COMPANY INC A A
12846 53854 MAGNESPEC INC. A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 1 03/14/1 P 8504314065 3249
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DF N SF9EH-N F
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS J 0 EA 0 U D
DF SMS J 0 EA 0 U SF9EH-N F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
063420 X 35355 P 595 Z 9 A H Z TRANSFORMERS NOI LESS THAN 25 LBS