| ADAQ |
BODY LENGTH |
3.062 INCHES NOMINAL |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
0.52 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-T-27 SPECIFICATION |
| AEHZ |
MAXIMUM OPERATING TEMP |
105.0 DEG CELSIUS |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
TAP W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
0.07 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-T-27/36 GOVERNMENT SPECIFICATION |
| ADAT |
BODY WIDTH |
2.625 INCHES NOMINAL |
| CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 300.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 400.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAU |
BODY HEIGHT |
4.250 INCHES NOMINAL |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
14 TAB, SOLDER LUG |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| PKWT |
UNPACKAGED UNIT WEIGHT (NON-CORE) |
4.625 POUNDS |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL SINGLE COMPONENT |