| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CRBZ |
WINDING OPERATING CURRENT |
1.2 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ACZB |
FREQUENCY RATING |
57.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ADAU |
BODY HEIGHT |
5.250 INCHES NOMINAL |
| AEHZ |
MAXIMUM OPERATING TEMP |
105.0 DEG CELSIUS |
| ADAQ |
BODY LENGTH |
3.938 INCHES NOMINAL |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
14 PIN |
| CRBZ |
WINDING OPERATING CURRENT |
1.3 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
108.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 101.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 122.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| ADAT |
BODY WIDTH |
2.438 INCHES NOMINAL |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |