| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ACZB |
FREQUENCY RATING |
800.0 HERTZ NOMINAL SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
25.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| ADAQ |
BODY LENGTH |
2.750 INCHES MAXIMUM |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
11.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
1.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 17.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 19.60 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
11.2 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| ABKW |
OVERALL HEIGHT |
1.900 INCHES NOMINAL |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
1.4 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.040 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.060 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
400.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ADAT |
BODY WIDTH |
1.400 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
14 PIN |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AEHZ |
MAXIMUM OPERATING TEMP |
170.0 DEG CELSIUS |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.390 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
2.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 44.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 46.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |