| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ACZX |
WINDING SHIELDING METHOD |
CORE GROUNDED SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTD |
MOUNTING SLOT WIDTH |
0.250 INCHES NOMINAL SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 4TH SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
16 TAB, SOLDER LUG |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
TAP W/O CENTER TAP SINGLE COMPONENT 1ST PRIMARY |
| AXGY |
MOUNTING METHOD |
SLOT SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
24.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ADAQ |
BODY LENGTH |
3.750 INCHES NOMINAL |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
200.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
30.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
2.25 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
19.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
93.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY |
| ADAT |
BODY WIDTH |
3.250 INCHES MAXIMUM |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ADAU |
BODY HEIGHT |
3.125 INCHES NOMINAL |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
2.4 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
36.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
800.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |