| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
41.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
3.880 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
35.59 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
22.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 4TH SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
13.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| ADAU |
BODY HEIGHT |
4.750 INCHES NOMINAL |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ABTB |
MOUNTING HOLE DIAMETER |
0.201 INCHES NOMINAL SINGLE GROUP |
| ADAQ |
BODY LENGTH |
6.750 INCHES NOMINAL |
| CWJS |
WINDING OPERATING VOLTAGE |
35.62 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
15 TAB, SOLDER LUG |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
DELTA-DELTA |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
22.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| ADAT |
BODY WIDTH |
4.750 INCHES NOMINAL |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |