| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ABKW |
OVERALL HEIGHT |
2.500 INCHES MAXIMUM |
| BPLC |
WINDING FUNCTION AND QUANTITY |
2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| ADAQ |
BODY LENGTH |
2.984 INCHES MINIMUM AND 3.016 INCHES MAXIMUM |
| FEAT |
SPECIAL FEATURES |
TERMINAL TIED TO ONE END OF FUSE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
30.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
44.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
| ADAT |
BODY WIDTH |
2.953 INCHES MINIMUM AND 2.985 INCHES MAXIMUM |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
320.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
6.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| CRMJ |
WINDING POWER RATING |
1.85 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
0.18 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CBBL |
FEATURES PROVIDED |
COLOR CODED LEAD AND W/OVERLOAD PROTECTION |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
42.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
92.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.047 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.079 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
12 WIRE LEAD |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
| AKNA |
INCLOSURE TYPE |
OPEN |
| CRMJ |
WINDING POWER RATING |
29.44 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |