| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
25 TURRET |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| ACZF |
MAXIMUM TRANSFORMER POWER RATING |
194.7 VOLT-AMPERE SINGLE COMPONENT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CRMJ |
WINDING POWER RATING |
3.0 WATTS SINGLE COMPONENT 4TH SECONDARY |
| ADAT |
BODY WIDTH |
2.900 INCHES MAXIMUM |
| CBME |
CUBIC MEASURE (NON-CORE) |
24.006 CUBIC INCHES |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
15.0 WATTS SINGLE COMPONENT 1ST SECONDARY |
| PKWT |
UNPACKAGED UNIT WEIGHT (NON-CORE) |
3.000 POUNDS |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
9.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
15.0 WATTS SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
16.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| CRMJ |
WINDING POWER RATING |
15.0 WATTS SINGLE COMPONENT 3RD SECONDARY |
| ADAQ |
BODY LENGTH |
3.780 INCHES MAXIMUM |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
DELTA-DELTA |
| ADAU |
BODY HEIGHT |
2.190 INCHES MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
| ABKW |
OVERALL HEIGHT |
2.409 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
16.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
9.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |
| AEHZ |
MAXIMUM OPERATING TEMP |
155.0 DEG CELSIUS |
| CRBZ |
WINDING OPERATING CURRENT |
300.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 4TH SECONDARY |
| FEAT |
SPECIAL FEATURES |
ONE PRIMARY AND EIGHT SECONDARIES |