5950-01-175-2450 ( 7904520-00 , 7904520-00 , 8797 )

NSN Information
NSN FSC NIIN Item Name INC
5950-01-175-2450 5950 011752450 TRANSFORMER,POWER 3249
NSN Features
MRC Parameter Characteristics
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAQ BODY LENGTH 2.330 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 75.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY
CRBZ WINDING OPERATING CURRENT 500.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
CRBZ WINDING OPERATING CURRENT 9.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
AASA THREAD LENGTH (NON-CORE) 0.325 INCHES MINIMUM SINGLE GROUP
ACZB FREQUENCY RATING 4.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 5.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT ALL PRIMARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT AND INTERNAL SHIELD CONNECTED TO SECONDARY TERMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 145.80 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
ADAU BODY HEIGHT 2.500 INCHES MAXIMUM
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
TTQY TERMINAL TYPE AND QUANTITY 13 TURRET
CRMJ WINDING POWER RATING 544.0 WATTS SINGLE COMPONENT SINGLE SECONDARY
CRMJ WINDING POWER RATING 2.0 WATTS SINGLE COMPONENT 2ND PRIMARY
ADAT BODY WIDTH 1.750 INCHES MAXIMUM
BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
7904520-00 90536 A 9 5 5 TX
7904520-00 06401 A 2 5 5 TX
8797 05254 A 2 3 5 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
7904520-00 90536 LOCKHEED MARTIN CORPORATION A A
7904520-00 06401 L-3 COMMUNICATIONS CORPORATION F A
8797 05254 AMI/COAST MAGNETICS INC A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 1 03/29/1 P 3249
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS I
DN 9B----- N
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 0 EA 0 U 9B----- N
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
063420 X 35355 P 595 Z 9 A H Z TRANSFORMERS NOI LESS THAN 25 LBS