| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
7 STANDOFF, SOLDER LUG |
| CRBZ |
WINDING OPERATING CURRENT |
500.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY |
| ABHP |
OVERALL LENGTH |
2.630 INCHES MINIMUM AND 2.750 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
2.250 INCHES MINIMUM AND 2.380 INCHES MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| ACZB |
FREQUENCY RATING |
54.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
| AEHZ |
MAXIMUM OPERATING TEMP |
105.0 DEG CELSIUS |
| ADAU |
BODY HEIGHT |
3.690 INCHES MINIMUM AND 3.810 INCHES MAXIMUM |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
VIBRATION RESISTANT |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.125 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
70.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |