| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ADAU |
BODY HEIGHT |
1.810 INCHES MAXIMUM |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
5.0 VOLTS SINGLE COMPONENT 1ST SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
7.9 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| FEAT |
SPECIAL FEATURES |
THREE PRIMARY WINDINGS; EIGHT SECONDARY WINDINGS |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.020 SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
700.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
20.0 VOLTS SINGLE COMPONENT 4TH SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT ALL PRIMARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT ALL SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| AEHZ |
MAXIMUM OPERATING TEMP |
130.0 DEG CELSIUS |
| ACZB |
FREQUENCY RATING |
20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
310.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
3 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
33 WIRE HOOK |
| ADAT |
BODY WIDTH |
1.750 INCHES MAXIMUM |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.300 SINGLE COMPONENT 4TH SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.112 INCHES SINGLE GROUP |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
17.0 VOLTS SINGLE COMPONENT 2ND SECONDARY |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.400 SINGLE COMPONENT 3RD SECONDARY |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
34.67 VOLTS SINGLE COMPONENT ALL PRIMARY |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.200 SINGLE COMPONENT 2ND SECONDARY |
| ADAQ |
BODY LENGTH |
2.570 INCHES MAXIMUM |
| CRCP |
PEAK VOLTAGE RATING (NON-CORE) |
17.0 VOLTS SINGLE COMPONENT 3RD SECONDARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABHP |
OVERALL LENGTH |
3.270 INCHES MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 4TH SECONDARY |
| CRGS |
DC RESISTANCE RATING IN OHMS |
0.070 SINGLE COMPONENT ALL PRIMARY |