| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
20 PIN |
| CQPZ |
WINDING CONDUCTOR SIZE |
0.00198 INCHES AMERICAN WIRE GAGE 2ND COMPONENT ALL SECONDARY |
| ACZB |
FREQUENCY RATING |
340.0 KILOHERTZ NOMINAL 2ND COMPONENT |
| BKPL |
RATING METHOD |
ELECTRICAL ALL COMPONENTS ALL SECONDARY AND WINDING TURNS ALL COMPONENTS ALL SECONDARY |
| ASKA |
COMPONENT NAME AND QUANTITY (NON-CORE) |
2 TRANSFORMER |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| ADAT |
BODY WIDTH |
0.980 INCHES MINIMUM AND 1.020 INCHES MAXIMUM |
| CQPZ |
WINDING CONDUCTOR SIZE |
0.00198 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE PRIMARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| TEST |
TEST DATA DOCUMENT |
95105-207-0031 DRAWING |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACYW |
IMPEDANCE RATING IN OHMS |
2370.0 NOMINAL 1ST COMPONENT SINGLE SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| ABHY |
TURN QUANTITY |
36 1ST COMPONENT SINGLE SECONDARY |
| ABHY |
TURN QUANTITY |
18 1ST COMPONENT ALL PRIMARY |
| ACZH |
PRIMARY TO SECONDARY TURN RATIO |
1 TO 2 1ST COMPONENT |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP 1ST COMPONENT SINGLE SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY 2ND COMPONENT AND 2 SECONDARY 2ND COMPONENT |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
250.0 MILLIWATTS 1ST COMPONENT ALL PRIMARY |
| ACYW |
IMPEDANCE RATING IN OHMS |
4000.0 NOMINAL 2ND COMPONENT ALL PRIMARY |
| ABHY |
TURN QUANTITY |
34 2ND COMPONENT SINGLE PRIMARY |
| ACYW |
IMPEDANCE RATING IN OHMS |
100.0 NOMINAL 1ST COMPONENT ALL PRIMARY |
| ACYW |
IMPEDANCE RATING IN OHMS |
1000.0 NOMINAL 2ND COMPONENT SINGLE SECONDARY |
| CQPZ |
WINDING CONDUCTOR SIZE |
0.01003 INCHES AMERICAN WIRE GAGE 1ST COMPONENT ALL PRIMARY |
| CQPZ |
WINDING CONDUCTOR SIZE |
0.01003 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE SECONDARY |
| AARD |
DUMMY TERMINAL QUANTITY (NON-CORE) |
2 |
| CQJX |
NOMINAL THREAD SIZE |
0.112 INCHES SINGLE GROUP |
| ACZL |
PULSE RISE TIME IN MICROSECONDS (NON-CORE) |
0.060 1ST COMPONENT |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP 2ND COMPONENT ALL SECONDARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP 2ND COMPONENT SINGLE PRIMARY |
| BKPL |
RATING METHOD |
ELECTRICAL ALL COMPONENTS ALL PRIMARY AND WINDING TURNS ALL COMPONENTS ALL PRIMARY |
| ACZB |
FREQUENCY RATING |
15.0 KILOHERTZ MINIMUM 1ST COMPONENT AND 6.0 MEGAHERTZ MAXIMUM 1ST COMPONENT |
| ADAQ |
BODY LENGTH |
1.780 INCHES MINIMUM AND 1.820 INCHES MAXIMUM |
| ADAU |
BODY HEIGHT |
0.865 INCHES NOMINAL |
| ABHY |
TURN QUANTITY |
68 2ND COMPONENT ALL SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZH |
PRIMARY TO SECONDARY TURN RATIO |
2 TO 1 2ND COMPONENT |
| BPLC |
WINDING FUNCTION AND QUANTITY |
2 PRIMARY 1ST COMPONENT AND 1 SECONDARY 1ST COMPONENT |