5950-01-356-5237 ( ITP-1452-21 , 10124753-104 )

NSN Information
NSN FSC NIIN Item Name INC
5950-01-356-5237 5950 013565237 TRANSFORMER,POWER 3249
NSN Features
MRC Parameter Characteristics
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 15.80 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 5.50 DC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
ADAV OVERALL DIAMETER 1.510 INCHES MAXIMUM
CBME CUBIC MEASURE (NON-CORE) 4.29 CUBIC INCHES
AKNA INCLOSURE TYPE FULLY INCLOSED
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 4TH SECONDARY
CRMJ WINDING POWER RATING 0.97 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRMJ WINDING POWER RATING 14.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
ACZB FREQUENCY RATING 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRMJ WINDING POWER RATING 12.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
CRBZ WINDING OPERATING CURRENT 2.6 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 62.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 31.60 DC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
CBBL FEATURES PROVIDED W/RECTIFIER
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 14 PIN
CRBZ WINDING OPERATING CURRENT 96.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY
AFFL MOUNTING BOLT CIRCLE DIAMETER 1.350 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ADAQ BODY LENGTH 0.600 INCHES MAXIMUM
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 70.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION FUNGUS RESISTANT AND MOISTURE RESISTANT
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
CRMJ WINDING POWER RATING 2.88 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 0.38 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY
CWJS WINDING OPERATING VOLTAGE 30.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
ITP-1452-21 09969 A 2 5 6 TX
10124753-104 94580 A 2 3 A TX
Manufacturers
Part SKU Cage Manufacturer Type Status
ITP-1452-21 09969 VISHAY DALE ELECTRONICS INC. A A
10124753-104 94580 HONEYWELL INTERNATIONAL INC A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 1 04/06/1 P 3249
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DF N SF9EH-N F
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS J 0 EA 0 U D
DF SMS J 0 EA 0 U SF9EH-N F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC