5961-00-391-1049 ( 40329 , 210-4032 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5961-00-391-1049 | 5961 | 003911049 | TRANSISTOR | 2058 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AXGY | MOUNTING METHOD | TERMINAL |
| ABBH | INCLOSURE MATERIAL | METAL |
| CTMZ | SEMICONDUCTOR MATERIAL | SILICON |
| ABHP | OVERALL LENGTH | 0.410 INCHES MAXIMUM |
| ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| CTQX | CURRENT RATING PER CHARACTERISTIC | 100.00 MILLIAMPERES SOURCE CUTOFF CURRENT MAXIMUM |
| ADAV | OVERALL DIAMETER | 0.240 INCHES MAXIMUM |
| CTQN | VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 25.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN AND 25.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN AND 2.5 MAXIMUM BREAKDOWN VOLTAGE, EMITTER-TO-BASE, COLLECTOR OPEN |
| CTRD | POWER RATING PER CHARACTERISTIC | 125.0 MILLIWATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR MINIMUM |
| AYQS | TERMINAL CIRCLE DIAMETER | 0.081 INCHES MAXIMUM |
| CTSG | MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 100.0 DEG CELSIUS JUNCTION |
| TTQY | TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 40329 | 34371 | A | 2 | 3 | 5 | TX | |
| 210-4032 | 22003 | A | 9 | 5 | 5 | TX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 40329 | 34371 | INTERSIL CORPORATION | A | A |
| 210-4032 | 22003 | BROADCAST ELECTRONICS INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | X | A | 04/01/1 | N | 8541500080 | 2058 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9N----- | N | V | DISCONTINUED W/O REPLACEMENT | |
| DS | I | V | DISCONTINUED W/O REPLACEMENT |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | U | N | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | Y | 0 | EA | 0 | U | D | ||
| DN | SMS | V | 0 | EA | 0 | U | 9N----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 063025 | Z | 34525 | W | 658 | Z | 9 | A | H | Z | SEMICONDUCTORS/DEVICES NOI ETC |