5962-00-229-7313 ( SP616N , 83-1530-8005 , 67C700002 , SP616A , C5489A )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5962-00-229-7313 | 5962 | 002297313 | MICROCIRCUIT,DIGITAL | 3177 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CQSZ | INCLOSURE CONFIGURATION | DUAL-IN-LINE |
| CQWX | OUTPUT LOGIC FORM | DIODE-TRANSISTOR LOGIC |
| AFGA | OPERATING TEMP RANGE | +0.0/+85.0 DEG CELSIUS |
| AFJQ | STORAGE TEMP RANGE | -65.0/+125.0 DEG CELSIUS |
| ADAU | BODY HEIGHT | 0.120 INCHES NOMINAL |
| CSSL | DESIGN FUNCTION AND QUANTITY | 2 GATE, NAND |
| CQSJ | INCLOSURE MATERIAL | CERAMIC |
| CQZP | INPUT CIRCUIT PATTERN | DUAL 4 INPUT |
| CBBL | FEATURES PROVIDED | EXPANDABLE AND MONOLITHIC AND POSITIVE OUTPUTS |
| ADAQ | BODY LENGTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.245 INCHES MINIMUM AND 0.250 INCHES MAXIMUM |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| SP616N | 18324 | A | 2 | 5 | 5 | 48 | |
| 83-1530-8005 | 12578 | H | 9 | 5 | 5 | 48 | |
| 67C700002 | 02106 | H | 9 | 5 | 1 | KE | |
| SP616A | 18324 | A | 2 | 3 | 5 | KE | |
| C5489A | 18324 | A | 2 | 5 | 5 | KE |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| SP616N | 18324 | PHILIPS SEMICONDUCTORS INC | A | A |
| 83-1530-8005 | 12578 | MINNESOTA MINING AND MFG CO | A | H |
| 67C700002 | 02106 | MRL INC | A | H |
| SP616A | 18324 | PHILIPS SEMICONDUCTORS INC | A | A |
| C5489A | 18324 | PHILIPS SEMICONDUCTORS INC | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | 0 | X | A | 02/12/1 | N | 8542900000 | 3177 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | M | 1REF00- | N | N | DISPOSAL |
| DN | ------- | I | V | DISCONTINUED W/O REPLACEMENT |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | U | N | 0 | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | N32 | V | 1 | EA | 0 | U | ------- | D | |
| DN | N32 | V | 1 | EA | 0 | U | 1REF00- | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|