5962-01-119-0161 ( 977380-1 , 977380-1 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5962-01-119-0161 | 5962 | 011190161 | MICROCIRCUIT,LINEAR | 3177 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CQSZ | INCLOSURE CONFIGURATION | DUAL-IN-LINE |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED AND MONOLITHIC AND BURN IN AND POSITIVE OUTPUTS |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 250.0 MILLIWATTS |
| CSSL | DESIGN FUNCTION AND QUANTITY | 1 NETWORK |
| CZEN | VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 50.0 VOLTS MAXIMUM POWER SOURCE |
| ADAU | BODY HEIGHT | 0.140 INCHES MINIMUM AND 0.185 INCHES MAXIMUM |
| AFJQ | STORAGE TEMP RANGE | -55.0/+150.0 DEG CELSIUS |
| CQSJ | INCLOSURE MATERIAL | CERAMIC |
| TTQY | TERMINAL TYPE AND QUANTITY | 16 PRINTED CIRCUIT |
| ADAQ | BODY LENGTH | 0.840 INCHES MAXIMUM |
| TEST | TEST DATA DOCUMENT | 96906-MIL-STD-883 STANDARD |
| ADAT | BODY WIDTH | 0.220 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
| CTFT | CASE OUTLINE SOURCE AND DESIGNATOR | D-2 MIL-M-38510 |
| AFGA | OPERATING TEMP RANGE | +0.0/+65.0 DEG CELSIUS |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 977380-1 | 3B150 | A | 2 | 3 | 5 | TX | |
| 977380-1 | 49956 | A | 9 | 5 | 5 | TX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 977380-1 | 3B150 | RAYTHEON TECHNICAL SERVICES COMP | A | A |
| 977380-1 | 49956 | RAYTHEON COMPANY | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | Q | 09/16/1 | B | N | 8542900000 | 3177 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| Q | A | N | 0 | X | B |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | Z | 1 | EA | 0 | U | D | ||
| DN | SMS | Z | 1 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061700 | X | 73930 | J | 72D | Z | 9 | A | H | Z | ELEC APPLIANCES/INSTRUMENTS NOI |