5962-01-206-6259 ( UTO-441R , 583R154H63 , QBH-425B )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5962-01-206-6259 | 5962 | 012066259 | MICROCIRCUIT,LINEAR | 3177 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| ADAR | BODY OUTSIDE DIAMETER | 0.498 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 0.120 INCHES MINIMUM AND 0.165 INCHES MAXIMUM |
| CBBL | FEATURES PROVIDED | HIGH PERFORMANCE AND MONOLITHIC AND THIN FILM |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 800.0 MILLIWATTS |
| CQZP | INPUT CIRCUIT PATTERN | 1 INPUT |
| CZEN | VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 15.0 VOLTS NOMINAL INPUT |
| CQSJ | INCLOSURE MATERIAL | METAL |
| CTQX | CURRENT RATING PER CHARACTERISTIC | 15.00 MILLIAMPERES FORWARD CURRENT, NONREPETITIVE, MAXIMUM PEAK TOTAL VALUE MICROAMPERES |
| TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |
| CQSZ | INCLOSURE CONFIGURATION | CAN |
| CSSL | DESIGN FUNCTION AND QUANTITY | 1 AMPLIFIER, RADIO FREQUENCY |
| AFGA | OPERATING TEMP RANGE | -54.0/+85.0 DEG CELSIUS |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| UTO-441R | 24539 | A | 1 | C | AH | 5 | ZZ |
| 583R154H63 | 97942 | A | 2 | 3 | 6 | 9Z | |
| QBH-425B | 55257 | F | 1 | 5 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| UTO-441R | 24539 | AGILENT TECHNOLOGIES INC. | A | A |
| 583R154H63 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORA | A | A |
| QBH-425B | 55257 | RAMTEK CORP | A | F |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | Q | 3 | 04/20/1 | B | N | 8542900000 | 3177 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | N | I | |||
| DF | N | SF9EH-N | F |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| Q | A | N | 0 | X | B |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | Z | 1 | EA | 0 | U | D | ||
| DF | SMS | Z | 1 | EA | 0 | U | SF9EH-N | F |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061700 | X | 34580 | J | J | 72D | Z | Z | A | H | Z | ELEC APPLIANCES/INSTRUMENTS NOI |