5962-01-451-7611 ( CY7C199-15VI , 381439-1 , CY7C199-15V1 , IDT71256SA15YSCD2836 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5962-01-451-7611 | 5962 | 014517611 | MICROCIRCUIT,MEMORY | 4101 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CQSZ | INCLOSURE CONFIGURATION | DUAL-IN-LINE |
| CSWJ | WORD QUANTITY (NON-CORE) | 32888 |
| CZEN | VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 5.0 VOLTS NOMINAL INPUT |
| AFJQ | STORAGE TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
| AFGA | OPERATING TEMP RANGE | -40.0/+85.0 DEG CELSIUS |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | 32K X8 STATIC RAM, 15NS |
| CQWX | OUTPUT LOGIC FORM | COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC |
| CZER | MEMORY DEVICE TYPE | RAM |
| CRHL | BIT QUANTITY (NON-CORE) | 262144 |
| AGAV | END ITEM IDENTIFICATION | C12391 RSC DA E/I FSCM 7S976 |
| TTQY | TERMINAL TYPE AND QUANTITY | 28 GULLWING |
| CQSJ | INCLOSURE MATERIAL | PLASTIC |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| CY7C199-15VI | 65786 | A | 2 | 3 | 6 | ZZ | |
| 381439-1 | 37695 | A | 2 | 5 | 6 | ZZ | |
| CY7C199-15V1 | 65786 | A | 9 | 5 | 5 | ZZ | |
| IDT71256SA15YSCD2836 | 61772 | A | 2 | 3 | 6 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| CY7C199-15VI | 65786 | CYPRESS SEMICONDUCTOR CORPORATIO | A | A |
| 381439-1 | 37695 | RAYTHEON COMPANY | F | A |
| CY7C199-15V1 | 65786 | CYPRESS SEMICONDUCTOR CORPORATIO | A | A |
| IDT71256SA15YSCD2836 | 61772 | INTEGRATED DEVICE TECHNOLOGY INC | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | D | 12/31/1 | D | N | 8542900000 | 4101 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DF | N | SF9EH-N | F | ||
| DS | N | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| D | A | N | 0 | X | D |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | Z | 1 | EA | 0 | 7 | D | ||
| DF | SMS | Z | 1 | EA | 0 | 7 | SF9EH-N | F |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061045 | Z | 34580 | W | 738 | 3 | 9 | A | H | Z | BOARDS PRINTED CIRCUIT ELEC |