5962-01-574-9947 ( AD8313ARM , 91788060 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5962-01-574-9947 | 5962 | 015749947 | MICROCIRCUIT,LINEAR | 3177 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| FEAT | SPECIAL FEATURES | ANALOG DEVICE WITH WIDE BANDWIDTH, 0.1 GHZ TO 2.5 GHZ;HIGH DYNAMIC RANGE, 70 DB TO +/- 3.0 DB;HIGH ACCURACY, 1.0 DB OVER 65 DB RANGE @ 1.9 GHZ;FAST RESPONSE, 40 NS FULL SCALE TYPICAL;CONTROLLER MODE WITH ERROR OUTPUT;SCALING STABLE OVER SUPPLY AND TEMPERATURE;WIDE SUPPLY RNAGE, 2.7 V TO 5.5 V;LOW POWER, 40 MW AT 3 V;POWER DOWN FEATURE, 60 MW AT 3 V |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | 0.1 GHZ TO 2.5 GHZ 70 DB LOGARITHMIC DETECTOR/CONTROLLER |
| CSSL | DESIGN FUNCTION AND QUANTITY | 1 DETECTOR AND 1 AMPLIFIER, ANALOG |
| AFJQ | STORAGE TEMP RANGE | -65.0/+150.0 DEG CELSIUS |
| AFGA | OPERATING TEMP RANGE | -40.0/+85.0 DEG CELSIUS |
| AGAV | END ITEM IDENTIFICATION | RF TRANSMITTER POWER AMPLIFIER SETPOINT CONTROL AND LEVEL MONITORING;LOGARITHMIC AMPLIFIER FOR RSSI MEASUREMENT CLLULAR BASE STATIONS, RADIO LINK, RADAR |
| CBBL | FEATURES PROVIDED | AC COUPLED |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| AD8313ARM | 24355 | A | 2 | 3 | 4 | 9Z | |
| 91788060 | F6481 | A | 9 | 5 | 4 | ZF |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| AD8313ARM | 24355 | ANALOG DEVICES INC. | A | A |
| 91788060 | F6481 | THALES | E | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | Q | 3 | 06/17/2 | A | N | 8542900000 | 3177 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DF | N | SF9---N | F | ||
| DS | N | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| Q | A | N | 0 | X | A |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DF | SMS | J | 1 | EA | 0 | U | SF9---N | F | |
| DS | SMS | J | 1 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|