AGAR |
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG |
10.0 NOMINAL AS SUPPLIED |
AGAQ |
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG |
45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAD |
SECOND BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
HUES |
COLOR |
BLACK |
UKBG |
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS |
200.0 VOLTS PER MIL /0.001 INCH/ |
AGAF |
FOURTH BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAG |
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES |
4.270 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZY |
FOURTH BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
AFZX |
THIRD BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
FLEX |
FLEXIBILITY |
FLEXIBLE |
MATL |
MATERIAL |
RUBBER,NEOPRENE,RT-501,RAYCHEM CORP |
AGAQ |
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG |
10.0 NOMINAL AS SUPPLIED |
STYL |
STYLE DESIGNATOR |
TRANSITION-1 TO 4 CABLES |
AGAE |
THIRD BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZV |
FIRST BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZU |
MAIN BODY INSIDE DIAMETER |
1.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
AFZV |
FIRST BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
AGAA |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH |
3.640 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
CQBC |
MINIMUM TENSILE STRENGTH |
1500 POUNDS PER SQUARE INCH |
ADZC |
ENVIRONMENTAL PROTECTION |
SOLVENT RESISTANT AND MILDEW RESISTANT AND FLAME RESISTANT AND WATER RESISTANT |
AGAR |
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG |
15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZZ |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH |
4.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAB |
MAIN BODY WALL THICKNESS |
0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZW |
SECOND BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
AFZU |
MAIN BODY INSIDE DIAMETER |
2.190 INCHES MINIMUM AS SUPPLIED |
AFZY |
FOURTH BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX |
THIRD BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
AGAC |
FIRST BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZW |
SECOND BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
ABJH |
TEMP RATING |
-55.0 DEG CELSIUS |