| AGAF |
FOURTH BRANCH WALL THICKNESS |
0.040 INCHES MAXIMUM AS SUPPLIED |
| AGAE |
THIRD BRANCH WALL THICKNESS |
0.048 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAC |
FIRST BRANCH WALL THICKNESS |
0.040 INCHES MAXIMUM AS SUPPLIED |
| AFZW |
SECOND BRANCH INSIDE DIAMETER |
0.260 INCHES MINIMUM AS SUPPLIED |
| HUES |
COLOR |
BLACK |
| AGAG |
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES |
1.359 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |
| FEAT |
SPECIAL FEATURES |
INCLUDES MOLDING PORTS |
| FLEX |
FLEXIBILITY |
FLEXIBLE |
| AGAB |
MAIN BODY WALL THICKNESS |
0.048 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |
| AGAF |
FOURTH BRANCH WALL THICKNESS |
0.048 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| STYL |
STYLE DESIGNATOR |
TRANSITION-1 TO 4 CABLES |
| AFZU |
MAIN BODY INSIDE DIAMETER |
0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| MATL |
MATERIAL |
PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
| AGAA |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH |
1.045 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAG |
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES |
1.661 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZV |
FIRST BRANCH INSIDE DIAMETER |
0.260 INCHES MINIMUM AS SUPPLIED |
| AFZV |
FIRST BRANCH INSIDE DIAMETER |
0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAB |
MAIN BODY WALL THICKNESS |
0.060 INCHES MAXIMUM AS SUPPLIED |
| AGAC |
FIRST BRANCH WALL THICKNESS |
0.048 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAE |
THIRD BRANCH WALL THICKNESS |
0.032 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |
| AGAE |
THIRD BRANCH WALL THICKNESS |
0.040 INCHES MAXIMUM AS SUPPLIED |
| AFZZ |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH |
0.865 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |
| AGAB |
MAIN BODY WALL THICKNESS |
0.072 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZW |
SECOND BRANCH INSIDE DIAMETER |
0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAF |
FOURTH BRANCH WALL THICKNESS |
0.032 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |
| AGAC |
FIRST BRANCH WALL THICKNESS |
0.032 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |
| AFZZ |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH |
0.950 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZU |
MAIN BODY INSIDE DIAMETER |
0.520 INCHES MINIMUM AS SUPPLIED |
| AGAA |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH |
0.855 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY |