| AGAR |
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG |
10.0 NOMINAL AS SUPPLIED |
| AGAQ |
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG |
45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| CQBC |
MINIMUM TENSILE STRENGTH |
1200 POUNDS PER SQUARE INCH |
| AGAD |
SECOND BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| HUES |
COLOR |
BLACK |
| AGAF |
FOURTH BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAG |
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES |
4.270 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AFZY |
FOURTH BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
| AFZX |
THIRD BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FLEX |
FLEXIBILITY |
FLEXIBLE |
| AGAQ |
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG |
10.0 NOMINAL AS SUPPLIED |
| STYL |
STYLE DESIGNATOR |
TRANSITION-1 TO 4 CABLES |
| AGAE |
THIRD BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AFZV |
FIRST BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZU |
MAIN BODY INSIDE DIAMETER |
1.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AFZV |
FIRST BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
| UKBG |
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS |
225.0 VOLTS PER MIL /0.001 INCH/ |
| AGAA |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH |
3.640 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAR |
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG |
15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| MATL |
MATERIAL |
PLASTIC,POLYOLEFIN,RT-1304,RAYCHEM CORP |
| AFZZ |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH |
4.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAB |
MAIN BODY WALL THICKNESS |
0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AFZW |
SECOND BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
| ADZC |
ENVIRONMENTAL PROTECTION |
FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND CORROSION RESISTANT AND WATER RESISTANT |
| AFZU |
MAIN BODY INSIDE DIAMETER |
2.190 INCHES MINIMUM AS SUPPLIED |
| AFZY |
FOURTH BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZX |
THIRD BRANCH INSIDE DIAMETER |
1.060 INCHES MINIMUM AS SUPPLIED |
| AGAC |
FIRST BRANCH WALL THICKNESS |
0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AFZW |
SECOND BRANCH INSIDE DIAMETER |
0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| ABJH |
TEMP RATING |
-55.0 DEG CELSIUS |