| AHRV |
TUBING WALL CONSTRUCTION STYLE |
CORRUGATED SINGLE TUBING SEGMENT |
| PRMT |
PRECIOUS MATERIAL |
SILVER |
| AHSF |
FLANGE QUANTITY |
2 |
| AHTX |
INSERTION LOSS IN DECIBELS |
0.25 |
| AHSY |
FLANGE INSIDE HEIGHT |
0.628 INCHES MINIMUM ALL FLANGES AND 0.631 INCHES MAXIMUM ALL FLANGES |
| ZZZV |
FSC APPLICATION DATA |
ANTENNAS,WAVEGUIDES AND RELATED EQUIPMENT |
| AHTD |
FLANGE DEPTH |
0.423 INCHES MINIMUM ALL FLANGES AND 0.453 INCHES MAXIMUM ALL FLANGES |
| SFTT |
SURFACE TREATMENT |
SILVER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.860 INCHES MINIMUM ALL FLANGES AND 1.890 INCHES MAXIMUM ALL FLANGES |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.169 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| CTCJ |
FLANGE STYLE |
COVER TYPE ALL FLANGES |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
M3922/53-4 ALL FLANGES |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.860 INCHES MINIMUM ALL FLANGES AND 1.890 INCHES MAXIMUM ALL FLANGES |
| AHSX |
FLANGE INSIDE WIDTH |
1.253 INCHES MINIMUM ALL FLANGES AND 1.256 INCHES MAXIMUM ALL FLANGES |
| STYL |
STYLE DESIGNATOR |
STRAIGHT TYPE |
| PMLC |
PRECIOUS MATERIAL AND LOCATION |
FLANGE OUTSIDE SURFACE AND TUBING OUTSIDE SURFACE SILVER |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| MATT |
MATERIAL |
ALUMINUM ALLOY ALL FLANGE |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.10 |
| FLEX |
FLEXIBILITY |
FLEXIBLE SINGLE TUBING SEGMENT |
| AHSE |
TUBING MANUFACTURER PART NUMBER (NON-CORE) |
M85/1-071 ALL TUBING SEGMENT |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| CTFD |
WAVEGUIDE LENGTH |
4.333 FEET NOMINAL |
| AFJN |
FRAGILITY FACTOR (NON-CORE) |
MODERATELY RUGGED |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |