| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
2 UNTHREADED HOLE SECOND FLANGE SECOND CONNECTION FACILITY |
| AAJD |
THREAD CLASS |
2B FIRST FLANGE FIRST CONNECTION FACILITY |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.20 |
| STYL |
STYLE DESIGNATOR |
BEND TYPE |
| AHSF |
FLANGE QUANTITY |
2 |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
0.321 INCHES NOMINAL |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
2 THREADED HOLE SECOND FLANGE FIRST CONNECTION FACILITY |
| AHRW |
TUBING TWIST TYPE |
STRAIGHT TWIST SINGLE TUBING SEGMENT |
| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION (NON-CORE) |
ERR-070 |
| THSD |
THREAD SERIES DESIGNATOR |
UNC FIRST FLANGE FIRST CONNECTION FACILITY |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SECOND FLANGE FIRST CONNECTION FACILITY |
| AAJD |
THREAD CLASS |
2B SECOND FLANGE FIRST CONNECTION FACILITY |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND FIRST FLANGE FIRST CONNECTION FACILITY |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.358 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
0.421 INCHES NOMINAL |
| AHSY |
FLANGE INSIDE HEIGHT |
0.319 NOMINAL MILS FIRST FLANGE AND 0.323 NOMINAL CENTIMETERS FIRST FLANGE |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SECOND FLANGE FIRST CONNECTION FACILITY |
| AHRX |
TUBING TWIST ANGLE IN DEG |
90.0 SINGLE TUBING SEGMENT |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES FIRST FLANGE FIRST CONNECTION FACILITY |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 THREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS SINGLE TUBING SEGMENT |
| FLEX |
FLEXIBILITY |
RIGID SINGLE TUBING SEGMENT |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.096 INCHES NOMINAL FIRST FLANGE SECOND CONNECTION FACILITY |
| AHTD |
FLANGE DEPTH |
0.235 INCHES MINIMUM FIRST FLANGE AND 0.255 INCHES MAXIMUM FIRST FLANGE |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
| CTCJ |
FLANGE STYLE |
CONTACT, DOUBLE RIDGE TYPE FIRST FLANGE |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
0.691 INCHES NOMINAL |
| SFTT |
SURFACE TREATMENT |
ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.095 INCHES MINIMUM SECOND FLANGE SECOND CONNECTION FACILITY AND 0.096 INCHES MAXIMUM SECOND FLANGE SECOND CONNECTION FACILITY |
| FEAT |
SPECIAL FEATURES |
NEITHER FLANGE PRESSURIZED |
| MATT |
MATERIAL |
ALUMINUM ALLOY SINGLE TUBING SEGMENT |
| CWBG |
WAVEGUIDE OFFSET DISTANCE |
14.430 NOMINAL MILS AND 14.490 NOMINAL CENTIMETERS |
| CSPL |
WAVEGUIDE LONGER OFFSET DISTANCE |
5.260 INCHES MINIMUM AND 5.320 INCHES MAXIMUM |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
0.791 INCHES NOMINAL |
| AHSX |
FLANGE INSIDE WIDTH |
0.689 INCHES MINIMUM FIRST FLANGE AND 0.693 INCHES MAXIMUM FIRST FLANGE |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.358 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SECOND FLANGE FIRST CONNECTION FACILITY |