| CGGK |
MOUNTING THREAD QUANTITY |
40 PER INCH |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 BRACKET |
| ASYC |
INSERTION LOSS AT MINIMUM ATTENUATION IN MAXIMUM DECIBELS |
0.2 |
| CQTQ |
ADJUSTMENT DEVICE TYPE AND QUANTITY |
1 SLOTTED SCREW |
| AAQL |
BODY STYLE |
WAVEGUIDE TYPE |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.500 INCHES NOMINAL |
| BNGR |
FREQUENCY RANGE |
33.000 GIGAHERTZ MINIMUM AND 50.000 GIGAHERTZ MAXIMUM |
| ASYD |
OVERALL ATTENUATION RANGE IN DECIBELS |
+0.2/+30.0 |
| AKPT |
WAVEGUIDE FLANGE TYPE |
COVER |
| ABHP |
OVERALL LENGTH |
1.500 INCHES NOMINAL |
| AJDB |
POWER RATING |
1.0 MILLIWATTS AVERAGE |
| ABMK |
OVERALL WIDTH |
0.875 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
-50.0/+220.0 DEG FAHRENHEIT |
| CRYY |
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER |
0.112 INCHES |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| ABKW |
OVERALL HEIGHT |
1.750 INCHES NOMINAL |
| ASYF |
ATTENUATION VARIATION METHOD |
CONTINUOUS |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.10 |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| AKSA |
WAVEGUIDE FLANGE DESIGNATION |
UG-599/U |
| AAFS |
APPLICATION DESIGN |
WAVEGUIDE |
| TTQY |
TERMINAL TYPE AND QUANTITY |
1 FLANGE |