| SFTT |
SURFACE TREATMENT |
PAINT SINGLE TUBING SEGMENT OUTSIDE SURFACES |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
8 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
| AHSZ |
FLANGE OUTSIDE WIDTH |
2.078 INCHES MAXIMUM SECOND FLANGE AND 2.108 INCHES MAXIMUM SECOND FLANGE |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.20 |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.578 INCHES MINIMUM FIRST FLANGE AND 1.608 INCHES MAXIMUM FIRST FLANGE |
| AHSF |
FLANGE QUANTITY |
3 |
| AHSX |
FLANGE INSIDE WIDTH |
0.899 INCHES MINIMUM THIRD FLANGE AND 0.901 INCHES MAXIMUM THIRD FLANGE |
| CTCJ |
FLANGE STYLE |
CONTACT TYPE ALL FLANGES |
| AHTD |
FLANGE DEPTH |
0.297 INCHES MAXIMUM SECOND FLANGE AND 0.327 INCHES MAXIMUM SECOND FLANGE |
| AHSY |
FLANGE INSIDE HEIGHT |
0.399 INCHES MINIMUM FIRST FLANGE AND 0.401 INCHES MAXIMUM FIRST FLANGE |
| AHSZ |
FLANGE OUTSIDE WIDTH |
2.078 INCHES MINIMUM FIRST FLANGE AND 2.108 INCHES MAXIMUM FIRST FLANGE |
| MATT |
MATERIAL |
COPPER SINGLE TUBING SEGMENT |
| MDCL |
MATERIAL DOCUMENT AND CLASSIFICATION (NON-CORE) |
MIL-C-81021 TEMPER HT MIL SPEC SINGLE MATERIAL RESPONSE ALL FLANGE |
| AAJD |
THREAD CLASS |
2B FIRST FLANGE SINGLE CONNECTION FACILITY |
| SFTT |
SURFACE TREATMENT |
NICKEL SINGLE TUBING SEGMENT INSIDE SURFACES |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
1.300 INCHES NOMINAL |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
DASH-1 FIRST FLANGE |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
0.900 INCHES NOMINAL |
| AHSY |
FLANGE INSIDE HEIGHT |
0.399 INCHES MINIMUM SECOND FLANGE AND 0.401 INCHES MAXIMUM SECOND FLANGE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC FIRST FLANGE SINGLE CONNECTION FACILITY |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
0.800 INCHES NOMINAL |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
8 UNTHREADED HOLE THIRD FLANGE SINGLE CONNECTION FACILITY |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS SINGLE TUBING SEGMENT |
| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION |
QQ-P-416,CLASS 1,TYPE 2 FED SPEC SINGLE TREATMENT RESPONSE ALL FLANGE OUTSIDE SURFACES AND WS9780-10001 MFR REF SINGLE TREATMENT RESPONSE ALL FLANGE OUTSIDE SURFACES |
| SFTT |
SURFACE TREATMENT |
CADMIUM ALL FLANGE OUTSIDE SURFACES AND PAINT ALL FLANGE OUTSIDE SURFACES |
| FLEX |
FLEXIBILITY |
RIGID SINGLE TUBING SEGMENT |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
| MDCL |
MATERIAL DOCUMENT AND CLASSIFICATION (NON-CORE) |
QQ-C-502,OXYGEN-FREE FED SPEC SINGLE MATERIAL RESPONSE SINGLE TUBING SEGMENT |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.578 INCHES MINIMUM THIRD FLANGE AND 1.608 INCHES MAXIMUM THIRD FLANGE |
| AHTD |
FLANGE DEPTH |
0.297 INCHES MINIMUM FIRST FLANGE AND 0.327 INCHES MAXIMUM FIRST FLANGE |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
DASH-2 SECOND FLANGE |
| ACJL |
BEND ANGLE IN DEG |
90.0 ALL BENDS E-PLANE |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
0.400 INCHES NOMINAL |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
DASH-2 THIRD FLANGE |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.193 INCHES MINIMUM THIRD FLANGE SINGLE CONNECTION FACILITY AND 0.199 INCHES MAXIMUM THIRD FLANGE SINGLE CONNECTION FACILITY |
| AHSZ |
FLANGE OUTSIDE WIDTH |
2.078 INCHES MINIMUM THIRD FLANGE AND 2.108 INCHES MAXIMUM THIRD FLANGE |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
8 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
| AHSY |
FLANGE INSIDE HEIGHT |
0.399 INCHES MINIMUM THIRD FLANGE AND 0.401 INCHES MAXIMUM THIRD FLANGE |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| MATT |
MATERIAL |
BERYLLIUM ALL FLANGE |
| AHSX |
FLANGE INSIDE WIDTH |
0.899 INCHES MINIMUM FIRST FLANGE AND 0.901 INCHES MAXIMUM FIRST FLANGE |
| CQGM |
MAXIMUM OPERATING PRESSURE |
5.0 POUNDS PER SQUARE INCH GAGE |
| AHTD |
FLANGE DEPTH |
0.297 INCHES MINIMUM THIRD FLANGE AND 0.327 INCHES MAXIMUM THIRD FLANGE |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.193 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY AND 0.199 INCHES MAXIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.578 INCHES MAXIMUM SECOND FLANGE AND 1.608 INCHES MAXIMUM SECOND FLANGE |
| AHSX |
FLANGE INSIDE WIDTH |
0.899 INCHES MINIMUM SECOND FLANGE AND 0.901 INCHES MAXIMUM SECOND FLANGE |