| CTCJ |
FLANGE STYLE |
CHOKE TYPE FIRST FLANGE |
| MATT |
MATERIAL |
COPPER ALLOY FOURTH TUBING SEGMENT AND FLANGE |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
0.746 INCHES MINIMUM AND 0.754 INCHES MAXIMUM |
| AHTD |
FLANGE DEPTH |
0.610 INCHES MINIMUM SECOND FLANGE AND 0.610 INCHES MAXIMUM SECOND FLANGE |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
| AHSF |
FLANGE QUANTITY |
2 |
| SFTT |
SURFACE TREATMENT |
PAINT ALL TUBING SEGMENT OUTSIDE SURFACES |
| AAJD |
THREAD CLASS |
2B SECOND FLANGE ALL CONNECTION FACILITIES |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
1.368 INCHES MINIMUM AND 1.376 INCHES MAXIMUM |
| AHSY |
FLANGE INSIDE HEIGHT |
0.493 INCHES MINIMUM SECOND FLANGE AND 0.501 INCHES MAXIMUM SECOND FLANGE |
| AHRW |
TUBING TWIST TYPE |
STRAIGHT TWIST THIRD TUBING SEGMENT |
| MATT |
MATERIAL |
ALUMINUM ALLOY THIRD TUBING SEGMENT |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS FIRST TUBING SEGMENT |
| FLEX |
FLEXIBILITY |
RIGID FIRST TUBING SEGMENT |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| AHSX |
FLANGE INSIDE WIDTH |
1.118 INCHES MINIMUM SECOND FLANGE AND 1.126 INCHES MAXIMUM SECOND FLANGE |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
0.618 INCHES MINIMUM AND 0.626 INCHES MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.169 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
| AHRX |
TUBING TWIST ANGLE IN DEG |
90.0 THIRD TUBING SEGMENT |
| CQGM |
MAXIMUM OPERATING PRESSURE |
15.0 POUNDS PER SQUARE INCH GAGE |
| FLEX |
FLEXIBILITY |
FLEXIBLE FOURTH TUBING SEGMENT |
| AHSX |
FLANGE INSIDE WIDTH |
1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
1.496 INCHES MINIMUM AND 1.504 INCHES MAXIMUM |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS THIRD TUBING SEGMENT |
| CTCJ |
FLANGE STYLE |
COVER TYPE SECOND FLANGE |
| MATT |
MATERIAL |
COPPER ALLOY SECOND TUBING SEGMENT |
| AHTX |
INSERTION LOSS IN DECIBELS |
0.10 |
| FLEX |
FLEXIBILITY |
FLEXIBLE SECOND TUBING SEGMENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SECOND FLANGE ALL CONNECTION FACILITIES |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| AHTD |
FLANGE DEPTH |
0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE |
| AHSY |
FLANGE INSIDE HEIGHT |
0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
| FLEX |
FLEXIBILITY |
RIGID THIRD TUBING SEGMENT |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.10 |
| MATT |
MATERIAL |
ALUMINUM ALLOY FIRST TUBING SEGMENT AND FLANGE |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
CORRUGATED FOURTH TUBING SEGMENT |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
CORRUGATED SECOND TUBING SEGMENT |
| ZZZV |
FSC APPLICATION DATA |
ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |