5985-01-167-0098 ( 1065585-13 , MDC8055-7 , 570997-071 , 292-7 , 292-7.0 , 40-403681-08 , 1065585-13 , 292-07-010 , 570997-071 , 50HF-007-SMA )

NSN Information
NSN FSC NIIN Item Name INC
5985-01-167-0098 5985 011670098 ATTENUATOR,FIXED 1422
NSN Features
MRC Parameter Characteristics
ASYN ATTENUATION ACCURACY IN DECIBELS -0.50/+0.50
BNGR FREQUENCY RANGE 0.000 HERTZ MINIMUM AND 8.000 GIGAHERTZ MAXIMUM
AHTZ OUTPUT IMPEDANCE RATING IN OHMS 50.0
AKNK VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE +0.0/+8.0 GIGAHERTZ
AHTW VOLTAGE STANDING WAVE RATIO 1.20
AXGY MOUNTING METHOD CONNECTOR
BBHS TERMINAL TYPE AND QUANTITY 2 CONNECTOR
AFGA OPERATING TEMP RANGE -65.0/+125.0 DEG CELSIUS
AAQL BODY STYLE ERR-090
ABHP OVERALL LENGTH 0.860 INCHES NOMINAL
AJDB POWER RATING 2.0 WATTS AVERAGE
AAFS APPLICATION DESIGN TRANSMISSION LINE
AHUC COAXIAL CONNECTOR SERIES DESIGNATION SMA
ASZN CONNECTION TYPE PER FUNCTION FEMALE OUTPUT AND MALE INPUT
ZZZK SPECIFICATION/STANDARD DATA 49956-570997 MANUFACTURERS SPECIFICATION CONTROL
AJDK RF SIGNAL ATTENUATION IN DECIBELS 7.0
ASZL FREQUENCY SENSITIVITY ATTENUATION IN DECIBELS NOT RATED
ASZM TEMPERATURE SENSITIVITY ATTENUATION IN DECIBELS NOT RATED
AAFZ BODY MATERIAL STEEL, STAINLESS
ADAV OVERALL DIAMETER 0.280 INCHES NOMINAL
ZZZV FSC APPLICATION DATA ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
ABEM BODY SURFACE TREATMENT ANY ACCEPTABLE
ASYE ATTENUATION ACCURACY REFERENCE FREQUENCY 8.0 GIGAHERTZ
AHTY INPUT IMPEDANCE RATING IN OHMS 50.0
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
1065585-13 49956 A 9 5 A TX
MDC8055-7 52335 A 2 5 5 TX
570997-071 49956 A 9 5 A TX
292-7 34078 A 9 5 5 TX
292-7.0 34078 A 2 5 E TX
40-403681-08 30890 H 9 5 A ZZ
1065585-13 3B150 A 2 3 A TX
292-07-010 34078 A 2 3 5 TX
570997-071 3B150 A 2 7 A TX
50HF-007-SMA 61162 A 2 5 5 ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
1065585-13 49956 RAYTHEON COMPANY A A
MDC8055-7 52335 DAL-TECH DEVICES INC. A A
570997-071 49956 RAYTHEON COMPANY A A
292-7 34078 EMERSON NETWORK POWER CONNECTIVI F A
292-7.0 34078 EMERSON NETWORK POWER CONNECTIVI F A
40-403681-08 30890 INTERLINK COMMUNICATIONS INC A H
1065585-13 3B150 RAYTHEON TECHNICAL SERVICES COMP A A
292-07-010 34078 EMERSON NETWORK POWER CONNECTIVI F A
570997-071 3B150 RAYTHEON TECHNICAL SERVICES COMP A A
50HF-007-SMA 61162 JFW INDUSTRIES INCORPORATED A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X D 1 11/21/1 P 8529109000 1422
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DA Z Q2200X- A
DN 9B----9 N
DF N SF9EH-N F
GP ------- C
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
D A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Z 0 EA 0 7 D
DA SMS Z 0 EA 0 7 Z Q2200X- A
GP SMS Z 0 EA 0 7 ------- C
DF SMS Z 0 EA 0 7 SF9EH-N F
DN SMS Z 0 EA 0 7 9B----9 N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061700 X 35325 J 723 Z 9 A H Z ELEC APPLIANCES/INSTRUMENTS NOI