| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION |
TT-P-1757 FED SPEC 2ND TREATMENT RESPONSE SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND MIL-C-5541 MIL SPEC 1ST TREATMENT RESPONSE SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND MIL-E-15090 MIL SPEC 3RD TREATMENT RESPONSE SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| AHSX |
FLANGE INSIDE WIDTH |
2.837 INCHES MINIMUM FIRST FLANGE AND 2.843 INCHES MAXIMUM FIRST FLANGE |
| MATT |
MATERIAL |
ALUMINUM ALLOY 6061 SINGLE TUBING SEGMENT AND FLANGE |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
8 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
| ZZZV |
FSC APPLICATION DATA |
RADAR SYSTEM |
| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION (NON-CORE) |
WS10094 FED SPEC SINGLE TREATMENT RESPONSE SINGLE TUBING SEGMENT INSIDE SURFACES |
| AHSX |
FLANGE INSIDE WIDTH |
2.837 INCHES MINIMUM SECOND FLANGE AND 2.843 INCHES MAXIMUM SECOND FLANGE |
| AHSF |
FLANGE QUANTITY |
2 |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.251 INCHES MINIMUM FIRST FLANGE SECOND CONNECTION FACILITY |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.276 INCHES MINIMUM FIRST FLANGE FIRST CONNECTION FACILITY AND 0.286 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
| AHSY |
FLANGE INSIDE HEIGHT |
0.452 INCHES MINIMUM FIRST FLANGE AND 0.458 INCHES MAXIMUM FIRST FLANGE |
| CTCJ |
FLANGE STYLE |
CONTACT TYPE FIRST FLANGE |
| AHSZ |
FLANGE OUTSIDE WIDTH |
3.730 INCHES MINIMUM SECOND FLANGE AND 3.770 INCHES MAXIMUM SECOND FLANGE |
| AHTD |
FLANGE DEPTH |
0.280 INCHES MINIMUM FIRST FLANGE AND 0.340 INCHES MAXIMUM FIRST FLANGE |
| AHSY |
FLANGE INSIDE HEIGHT |
0.586 INCHES MINIMUM SECOND FLANGE AND 0.592 INCHES MAXIMUM SECOND FLANGE |
| SFTT |
SURFACE TREATMENT |
ENAMEL SINGLE TUBING SEGMENT OUTSIDE SURFACES AND CHROMATE ZINC SINGLE TUBING SEGMENT OUTSIDE SURFACES AND CHROMATE SINGLE TUBING SEGMENT OUTSIDE SURFACES |
| CTCJ |
FLANGE STYLE |
CONTACT TYPE SECOND FLANGE |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.255 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
| AHTD |
FLANGE DEPTH |
0.280 INCHES MINIMUM SECOND FLANGE AND 0.340 INCHES MAXIMUM SECOND FLANGE |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.07 |
| STYL |
STYLE DESIGNATOR |
WAVEGUIDE TO WAVEGUIDE |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
| BBPN |
ADAPTER LENGTH |
2.282 INCHES MINIMUM AND 2.302 INCHES MAXIMUM |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
| AHSZ |
FLANGE OUTSIDE WIDTH |
3.580 INCHES MINIMUM FIRST FLANGE AND 3.620 INCHES MAXIMUM FIRST FLANGE |
| SFTT |
SURFACE TREATMENT |
VARNISH SINGLE TUBING SEGMENT INSIDE SURFACES |
| AHTA |
FLANGE OUTSIDE HEIGHT |
2.310 INCHES MINIMUM SECOND FLANGE AND 2.350 INCHES MAXIMUM SECOND FLANGE |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.780 INCHES MINIMUM FIRST FLANGE AND 1.820 INCHES MAXIMUM FIRST FLANGE |