| CTCJ |
FLANGE STYLE |
CHOKE TYPE FIRST FLANGE |
| CQGM |
MAXIMUM OPERATING PRESSURE |
60.0 POUNDS PER SQUARE INCH GAGE |
| AHTB |
FLANGE INSIDE DIAMETER |
1.126 INCHES MINIMUM FIRST FLANGE AND 1.156 INCHES MAXIMUM FIRST FLANGE |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.485 INCHES MINIMUM FIRST FLANGE AND 1.515 INCHES MAXIMUM FIRST FLANGE |
| CTFD |
WAVEGUIDE LENGTH |
6.880 INCHES MINIMUM AND 7.120 INCHES MAXIMUM |
| AHSF |
FLANGE QUANTITY |
2 |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
M3922/53-8 SECOND FLANGE |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.144 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
| AHSX |
FLANGE INSIDE WIDTH |
0.747 INCHES MINIMUM FIRST FLANGE AND 0.753 INCHES MAXIMUM FIRST FLANGE |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
0.372 INCHES MINIMUM AND 0.378 INCHES MAXIMUM |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
| AHSX |
FLANGE INSIDE WIDTH |
0.854 INCHES MINIMUM SECOND FLANGE |
| AAJD |
THREAD CLASS |
2B FIRST FLANGE SINGLE CONNECTION FACILITY |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
0.847 INCHES MINIMUM AND 0.853 INCHES MAXIMUM |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.485 INCHES MINIMUM FIRST FLANGE AND 1.515 INCHES MAXIMUM FIRST FLANGE |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
0.747 INCHES MINIMUM AND 0.753 INCHES MAXIMUM |
| AHSY |
FLANGE INSIDE HEIGHT |
0.479 INCHES MINIMUM SECOND FLANGE |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.485 INCHES MINIMUM SECOND FLANGE AND 1.515 INCHES MAXIMUM SECOND FLANGE |
| MATT |
MATERIAL |
ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC FIRST FLANGE SINGLE CONNECTION FACILITY |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.485 INCHES MINIMUM SECOND FLANGE AND 1.515 INCHES MAXIMUM SECOND FLANGE |
| AHSE |
TUBING MANUFACTURER PART NUMBER (NON-CORE) |
M85/1-083 SINGLE TUBING SEGMENT |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS SINGLE TUBING SEGMENT |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
| AGAV |
END ITEM IDENTIFICATION |
TRAINING SET,ELECTRONIC WARFARE AN/MST-T1V |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
M3922/59-11 FIRST FLANGE |
| STYL |
STYLE DESIGNATOR |
STRAIGHT TYPE |
| CTCJ |
FLANGE STYLE |
COVER TYPE SECOND FLANGE |
| AHTD |
FLANGE DEPTH |
0.485 INCHES MINIMUM FIRST FLANGE AND 0.515 INCHES MAXIMUM FIRST FLANGE |
| ZZZV |
FSC APPLICATION DATA |
RADAR EQUIPMENT |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
| AHSY |
FLANGE INSIDE HEIGHT |
0.372 INCHES MINIMUM FIRST FLANGE AND 0.378 INCHES MAXIMUM FIRST FLANGE |
| AHTD |
FLANGE DEPTH |
0.376 INCHES MINIMUM SECOND FLANGE AND 0.406 INCHES MAXIMUM SECOND FLANGE |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLEX |
FLEXIBILITY |
FLEXIBLE SINGLE TUBING SEGMENT |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
0.472 INCHES MINIMUM AND 0.478 INCHES MAXIMUM |
| AFJN |
FRAGILITY FACTOR (NON-CORE) |
MODERATELY DELICATE |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.12 |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81755-654VE7190 MANUFACTURERS SPECIFICATION CONTROL |