| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
2 UNTHREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY |
| AHSX |
FLANGE INSIDE WIDTH |
0.688 INCHES MINIMUM ALL FLANGES AND 0.694 INCHES MAXIMUM ALL FLANGES |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
M39000/3-074 FIRST FLANGE |
| SFTT |
SURFACE TREATMENT |
CHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
1.187 INCHES MINIMUM AND 1.193 INCHES MAXIMUM |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.20 |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.145 INCHES MINIMUM SECOND FLANGE SECOND CONNECTION FACILITY |
| AHSF |
FLANGE QUANTITY |
2 |
| CTFD |
WAVEGUIDE LENGTH |
1.900 INCHES MINIMUM AND 2.100 INCHES MAXIMUM |
| AHTR |
FLANGE MANUFACTURER PART NUMBER (NON-CORE) |
M39000/3-076 SECOND FLANGE |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 UNTHREADED HOLE SECOND FLANGE SECOND CONNECTION FACILITY |
| AAJD |
THREAD CLASS |
2B FIRST FLANGE SECOND CONNECTION FACILITY |
| AHSE |
TUBING MANUFACTURER PART NUMBER (NON-CORE) |
M23351/4-037 SINGLE TUBING SEGMENT |
| THSD |
THREAD SERIES DESIGNATOR |
UNC FIRST FLANGE SECOND CONNECTION FACILITY |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
1.087 INCHES MINIMUM AND 1.093 INCHES MAXIMUM |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND FIRST FLANGE SECOND CONNECTION FACILITY |
| MATT |
MATERIAL |
ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS SINGLE TUBING SEGMENT |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.096 INCHES MINIMUM ALL FLANGES FIRST CONNECTION FACILITY |
| CTCJ |
FLANGE STYLE |
CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
| FLEX |
FLEXIBILITY |
RIGID SINGLE TUBING SEGMENT |
| FEAT |
SPECIAL FEATURES |
FREQUENCY RANGE 7.5 TO 18.0 GHZ |
| AHTD |
FLANGE DEPTH |
0.235 INCHES MINIMUM ALL FLANGES AND 0.265 INCHES MAXIMUM ALL FLANGES |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES FIRST FLANGE SECOND CONNECTION FACILITY |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
4 THREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
| STYL |
STYLE DESIGNATOR |
STRAIGHT TYPE |
| AHTA |
FLANGE OUTSIDE HEIGHT |
1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
| AHSY |
FLANGE INSIDE HEIGHT |
0.318 INCHES MINIMUM ALL FLANGES AND 0.324 INCHES MAXIMUM ALL FLANGES |
| ZZZV |
FSC APPLICATION DATA |
RADAR EQUIPMENT |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
0.603 INCHES MINIMUM AND 0.609 INCHES MAXIMUM |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
0.503 INCHES MINIMUM AND 0.509 INCHES MAXIMUM |
| AHSZ |
FLANGE OUTSIDE WIDTH |
1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION (NON-CORE) |
MIL-C-5541 MIL SPEC SINGLE TREATMENT RESPONSE ALL TUBING SEGMENT AND FLANGE ALL SURFACES |