| FEAT |
SPECIAL FEATURES |
LFREQUENCY RANGE 2.7 TO 2.9 GHZ; THE UNIT SHALL BE CAPABLE OF CONTINUOUS HIGH POWER OPERATION WHEN EXPOSED TO INCIDENT POWER LEVELS OF 10 KILOWATTS, PEAK MAXIMUM 1.1 KILOWATT AVG. UNDER PRESSURIZATION CONDITIONS. |
| AHSX |
FLANGE INSIDE WIDTH |
2.835 INCHES MINIMUM ALL FLANGES AND 2.845 INCHES MAXIMUM ALL FLANGES |
| SFTT |
SURFACE TREATMENT |
CHROMATE FIRST TUBING SEGMENT OUTSIDE SURFACES AND PAINT FIRST TUBING SEGMENT OUTSIDE SURFACES |
| AHTD |
FLANGE DEPTH |
0.670 INCHES MINIMUM ALL FLANGES AND 0.710 INCHES MAXIMUM ALL FLANGES |
| CQHN |
WAVEGUIDE OUTSIDE WIDTH |
3.000 INCHES NOMINAL |
| CSRM |
WAVEGUIDE FIRST LEG LENGTH |
3.750 INCHES NOMINAL |
| AHSF |
FLANGE QUANTITY |
2 |
| AHRV |
TUBING WALL CONSTRUCTION STYLE |
SEAMLESS ALL TUBING SEGMENT |
| AHSY |
FLANGE INSIDE HEIGHT |
1.335 INCHES MINIMUM ALL FLANGES AND 1.345 INCHES MAXIMUM ALL FLANGES |
| CTFP |
WAVEGUIDE SECOND LEG LENGTH |
31.150 INCHES NOMINAL |
| MATT |
MATERIAL |
ALUMINUM ALLOY THIRD TUBING SEGMENT |
| CRLB |
WAVEGUIDE INSIDE HEIGHT |
1.340 INCHES NOMINAL |
| SFTT |
SURFACE TREATMENT |
CHROMATE THIRD TUBING SEGMENT OUTSIDE SURFACES AND PAINT THIRD TUBING SEGMENT OUTSIDE SURFACES |
| FLEX |
FLEXIBILITY |
RIGID FIRST TUBING SEGMENT |
| AHRX |
TUBING TWIST ANGLE IN DEG |
20.0 SECOND TUBING SEGMENT |
| CXBG |
WAVEGUIDE FOURTH LEG LENGTH |
5.370 INCHES NOMINAL |
| SFTT |
SURFACE TREATMENT |
CHROMATE ALL FLANGE OUTSIDE SURFACES AND PAINT ALL FLANGE OUTSIDE SURFACES |
| CRFH |
WAVEGUIDE INSIDE WIDTH |
2.840 INCHES NOMINAL |
| AHTX |
INSERTION LOSS IN DECIBELS |
0.06 |
| AHTN |
FLANGE CONNECTING HOLE DIAMETER |
0.257 INCHES NOMINAL ALL FLANGES ALL CONNECTION FACILITIES |
| AHTC |
FLANGE OUTSIDE DIAMETER |
3.000 INCHES NOMINAL ALL FLANGES |
| AHRW |
TUBING TWIST TYPE |
TWISTABLE SECOND TUBING SEGMENT |
| CWBP |
WAVEGUIDE THIRD LEG LENGTH |
10.250 INCHES NOMINAL |
| MATT |
MATERIAL |
COPPER ALLOY SECOND TUBING SEGMENT |
| FLEX |
FLEXIBILITY |
FLEXIBLE SECOND TUBING SEGMENT |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLEX |
FLEXIBILITY |
RIGID THIRD TUBING SEGMENT |
| MATT |
MATERIAL |
ALUMINUM ALLOY ALL FLANGE |
| AHTW |
VOLTAGE STANDING WAVE RATIO |
1.10 |
| MATT |
MATERIAL |
ALUMINUM ALLOY FIRST TUBING SEGMENT |
| CSQT |
FLANGE CONNECTING FACILITY AND QUANTITY |
8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
| CSFC |
WAVEGUIDE OUTSIDE HEIGHT |
1.500 INCHES NOMINAL |
| CTCJ |
FLANGE STYLE |
CHOKE TYPE ALL FLANGES |
| STYL |
STYLE DESIGNATOR |
THREE BEND TYPE |