| FTLD |
FUNCTIONAL DESCRIPTION |
MODEL 5850 RF HEAT EXCHANGER IS A MODEL 9750 50 OHM RESISTOR ASSEMBLY COOLED BY A VENTED, CLOSED-LOOP WATER SYSTEM, UTILIZING A CENTRIFUGAL PUMP, WATER-TO-AIR HEAT EXCHANGER, CAPACITY OF COOLANT IS APPROX 11 US GALLONS, AND 1 CENTRIFUGAL BLOWER; BLOWER ASSY IS A 1.5 HP BELT-DRIVEN CENTRIFUGAL BLOWER, BLOWER MOVES AIR INTO A CLOSED PLENUM, THROUGH THE HEAT EXCHANGER COIL TO THE REAR OF UNIT |
| ACYW |
IMPEDANCE RATING IN OHMS |
50.0 NOMINAL |
| AKRZ |
TERMINATION TYPE |
CONNECTOR |
| BFMF |
COOLING METHOD |
FORCED LIQUID |
| FEAT |
SPECIAL FEATURES |
FAC POWER REQUIREMENTS 230 VAC, SINGLE PHASE 27.5 AMP; 208-230/460 VAC, THREE PHASE 9.6/4.8 AMP; FINISH BEIGE SPLATTER; FAN 1.5 HP CENTRIFUGAL; PUMP 1.5 HP CENTRIFUGAL; VSWR 60 HZ TO 800MHZ 1.1:1 MAX |
| SUPP |
SUPPLEMENTARY FEATURES |
LOCATION SHOULD BE DRY, FREE OF EXCESSIVE DUST AND AMBIENT TEMP P5.0 TO 35 DEG C WITH WATER ONLY AND M20.0 TO 30.0 DEG C WITH PORM 35 PCT ETHYLENE GLYCOL MIXTURE; ROOM WELL VENTILATED; RF DISSIPATION OF UNIT IS 50,000 WATTS EQUALS 170.650 BTU/HR USUALLY DUCTED OUT OF BUILDING; NOT NECESSARY TO MOUNT WHICH IS DESIGNED TO BE A FREE-STANDING DEVICE RESTING ON 4 HEAVY DUTY CASTERS; BRAKES ARE INSTALLED ON SWIVEL CASTERS; 4 TERMINAL, CAPTIVE-SCREW TERMINAL STRIP |
| AJDB |
POWER RATING |
50.000 KILOWATTS AVERAGE |