| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
CABLE ASSEMBLY TLC 50 OHM |
| PMLC |
PRECIOUS MATERIAL AND LOCATION |
.000030 INCH THICK MIN PLATING ON RECEPTACLE CONTACTS GOLD AND SIGNAL AND GRND CONDUCTORS PLATED WITH SILVER SILVER |
| CXDC |
ROUND CONDUCTOR SIZE |
30 AWG ALL CONDUCTORS |
| AMQN |
CONDUCTOR QUANTITY |
25 |
| CXDQ |
CONDUCTOR ARRANGEMENT AND QUANTITY |
25 MOLDED |
| CXCW |
CONDUCTOR FORM |
SOLID ALL CONDUCTORS |
| FEAT |
SPECIAL FEATURES |
HOUSING CONTAINS STANDARD PRESSURE COPPER ALLOY RECEPTACLE CONTACTS PLATED WITH .000030 INCH MIN THICK GOLD OVER .000050 INCH MIN THICK NICKEL IN MATING AREA; P2 CONN MUST MATE AND LATCH TO AMP PART NO 1-102158-0; P1 AND P2 CONN HOUSING SHALL BE THERMOPLASTIC; HOUSING IS A 50 POSITION HEADER; PULL TABS SHALL BE PROVIDED; CABLE SHALL BE 50 OHM TRANSMISSION LINE; 25 SIGNAL COND 30 AWG SILVER PLATED COPPER;50 GRND COND 32 AWG SILVER PLATED COPPER; 50 +-5 OHM IMPEDANCE;28 PICO-FARADS CAPACITANCE;14 NANOSECONDS PER FOOT PROPAGATION DELAY;PIN 1 SHALL BE CLEARLY IDENTIFIED ON P1 AND P2;RESISTANCE OF CABLE ASSEMBLY SHALL BE LESS THAN .21 OHMS FOR SIGNAL CONDS AND LESS THAN .18 OHMS FOR GRND CONDS;CABLE ASSEMBLIES SHALL BE ABLE TO WITHSTAND 300 VDC BETWEEN ANY ADJACENT SIGNAL AND/OR GRND PATHS; IMPEDANCE OF CABLE ASSEMBLY SHALL BE 50 +-5 OHMS; |
| MATT |
MATERIAL |
COPPER CORE CONDUCTOR ALL CONDUCTORS AND SILVER CORE CONDUCTOR ALL CONDUCTORS |
| PRMT |
PRECIOUS MATERIAL |
GOLD AND SILVER |
| AKRZ |
TERMINATION TYPE |
CONNECTOR RECEPTACLE BOTH ENDS ALL CONDUCTORS |
| AGTK |
CENTER TO CENTER DISTANCE BETWEEN TERMINAL HOLES |
0.100 INCHES NOMINAL |