5999-00-001-5985 ( L754 , 537754-1 , SP104 )
NSN Information
NSN | FSC | NIIN | Item Name | INC |
---|---|---|---|---|
5999-00-001-5985 | 5999 | 000015985 | DELAY LINE | 0637 |
NSN Features
MRC | Parameter | Characteristics |
---|---|---|
ANSL | INPUT IMPEDANCE RATING | 200.000 OHMS |
ZZZV | FSC APPLICATION DATA | AUTOMATED RADAR TERMINAL SYSTEM ARTS III-DATA ENTRY AND DISPLAY SYBSYSTEM,TYPE I AND II DISPLAY |
BHTH | ATTENUATION IN DECIBELS | 10.000 |
BZWM | SIGNAL DELAY METHOD | INDUCTANCE |
CCFF | TERMINAL TYPE AND QUANTITY | 4 WIRE LEADS |
ANNQ | MATERIAL AND LOCATION | PLASTIC CASE |
ANSR | OUTPUT IMPEDANCE RATING | 200.000 OHMS |
CCDX | PULSE RISE TIME RATING | 40.0 NANOSECONDS |
ANNR | SURFACE TREATMENT AND LOCATION | PLASTIC OVERALL |
AAUB | HOLE DIAMETER | 0.018 INCHES NOMINAL |
BBBW | MOUNTING PROVISION ARRANGEMENT STYLE | 2 POSITION IN-LINE |
CCDQ | SECTION DELAY TIME | 150.000 NANOSECONDS 1ST PRIMARY NANOAMPERES |
AZGM | MOUNTING FACILITY | TERMINAL |
ACZB | FREQUENCY RATING | NOT RATED |
AAQL | BODY STYLE | RECTANGULAR |
ARBR | BODY DEPTH | 0.225 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.320 INCHES NOMINAL |
AFBH | INDIVIDUAL SECTION QUANTITY | 1 |
AMSE | VOLTAGE RATING | NOT RATED |
CCDT | DELAY TIME VARIATION PER DEG CELSIUS | NOT RATED |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.200 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 |
AFGA | OPERATING TEMP RANGE | NOT RATED |
APQL | FREQUENCY BANDWIDTH | 360.0 HERTZ NOMINAL |
ADAQ | BODY LENGTH | 0.750 INCHES NOMINAL |
Manufacturing Part Numbers (SKUs)
Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
---|---|---|---|---|---|---|---|
L754 | 52494 | A | 2 | 3 | 5 | 48 | |
537754-1 | 96214 | A | 2 | 5 | 5 | 48 | |
SP104 | 16714 | A | 2 | 5 | 5 | 48 |
Manufacturers
Part SKU | Cage | Manufacturer | Type | Status |
---|---|---|---|---|
L754 | 52494 | WHITE CONSOLIDATED INDUSTRIES IN | A | A |
537754-1 | 96214 | RAYTHEON COMPANY | F | A |
SP104 | 16714 | RHOMBUS INDUSTRIES INC | A | A |
FLIS Identification
PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
---|---|---|---|---|---|---|---|---|---|---|
U | X | D | 1 | 10/04/1 | P | 8543909000 | 0637 |
FLIS Management
MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
---|
Demilitarization Codes & Management
DML | PMI | HMIC | ADP | CC | ESDC |
---|
Miscellaneous Management
MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
---|
Management Control Army
MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
---|
Freight
NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
---|---|---|---|---|---|---|---|---|---|---|---|---|