5999-00-021-6267 ( N1023 , 577R703H02 , N1023 )
NSN Information
NSN | FSC | NIIN | Item Name | INC |
---|---|---|---|---|
5999-00-021-6267 | 5999 | 000216267 | SHIELDING GASKET,ELECTRONIC | 2028 |
NSN Features
MRC | Parameter | Characteristics |
---|---|---|
STYL | STYLE DESIGNATOR | NON-CIRCULAR |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ERR-090 |
BQBN | EDGE RADIUS | 0.063 INCHES NOMINAL |
ADPW | OUTSIDE CORNER RADIUS | 0.063 INCHES NOMINAL |
ADVN | CROSS-SECTIONAL HEIGHT | 0.079 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.817 INCHES NOMINAL |
CTNJ | ENVIRONMENTAL PROTECTION MATERIAL LOCATION | THROUGHOUT RF SHIELDING GASKET |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-R-3065,TYPE S,CLASS T.A.,GRADE 605-A6,B3,E3,F2 AND Z MFR REF SINGLE MATERIAL RESPONSE ENVIRONMENTAL SEAL |
ABHP | OVERALL LENGTH | 1.248 INCHES NOMINAL |
ADUF | APERTURE LENGTH | 0.998 INCHES NOMINAL |
ADUE | APERTURE WIDTH | 0.567 INCHES NOMINAL |
MATT | MATERIAL | RUBBER SILICONE CLASS Q ENVIRONMENTAL SEAL |
Manufacturing Part Numbers (SKUs)
Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
---|---|---|---|---|---|---|---|
N1023 | 24664 | A | 2 | 3 | 5 | TX | |
577R703H02 | 97942 | A | 2 | 7 | 5 | TX | |
N1023 | 07195 | H | 1 | C | AC | 5 | ZZ |
Manufacturers
Part SKU | Cage | Manufacturer | Type | Status |
---|---|---|---|---|
N1023 | 24664 | JONAL LABORATORIES INCORPORATED | A | A |
577R703H02 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORA | A | A |
N1023 | 07195 | RELIANCE ELECTRIC CO | A | H |
FLIS Identification
PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
---|---|---|---|---|---|---|---|---|---|---|
U | X | A | 1 | 05/10/1 | P | 8543909000 | 2028 |
FLIS Management
MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
---|---|---|---|---|---|
DS | I | X | FORMERLY 5330-00-021-6267 | ||
DN | 9B----- | N | X | FORMERLY 5330-00-021-6267 |
Demilitarization Codes & Management
DML | PMI | HMIC | ADP | CC | ESDC |
---|---|---|---|---|---|
A | U | P | X |
Miscellaneous Management
MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
---|---|---|---|---|---|---|---|---|---|
DS | SMS | J | 1 | EA | 0 | U | D | ||
DN | SMS | J | 1 | EA | 0 | U | 9B----- | N |
Management Control Army
MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
---|
Freight
NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
---|---|---|---|---|---|---|---|---|---|---|---|---|
194120 | Z | 95110 | W | 596 | Z | 9 | A | V | Z | WASHERS/GASKETS/PCKG DVCS NOI |