5999-01-013-8561 ( X69-218 , 247AS-C0560-001 , 247AS-C0560-001 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5999-01-013-8561 | 5999 | 010138561 | DELAY LINE | 0637 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| ADAQ | BODY LENGTH | 1.300 INCHES MAXIMUM |
| APQL | FREQUENCY BANDWIDTH | NOT RATED |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.200 INCHES NOMINAL |
| CCDQ | SECTION DELAY TIME | 40.000 NANOSECONDS 1ST PRIMARY NANOAMPERES |
| CCFF | TERMINAL TYPE AND QUANTITY | 4 PIN |
| CCDX | PULSE RISE TIME RATING | NOT RATED |
| BZWM | SIGNAL DELAY METHOD | LUMPED CONSTANT |
| ADAT | BODY WIDTH | 0.510 INCHES MAXIMUM |
| AZGM | MOUNTING FACILITY | TERMINAL |
| ACZB | FREQUENCY RATING | NOT RATED |
| AAQL | BODY STYLE | RECTANGULAR |
| ANNQ | MATERIAL AND LOCATION | PLASTIC, EPOXY RESIN BODY |
| ARBR | BODY DEPTH | 0.230 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
| AFBH | INDIVIDUAL SECTION QUANTITY | 1 |
| ANSR | OUTPUT IMPEDANCE RATING | 100.000 OHMS |
| ANSL | INPUT IMPEDANCE RATING | 100.000 OHMS |
| AMSE | VOLTAGE RATING | 100.000 VOLTS NOMINAL |
| CCDT | DELAY TIME VARIATION PER DEG CELSIUS | NOT RATED |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.000 INCHES NOMINAL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| BBBW | MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
| AFGA | OPERATING TEMP RANGE | -55.0/+100.0 DEG CELSIUS |
| BHTH | ATTENUATION IN DECIBELS | 1.000 |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| X69-218 | 11253 | H | 9 | 5 | 5 | TX | |
| 247AS-C0560-001 | 30003 | A | 2 | 3 | 1 | TX | |
| 247AS-C0560-001 | 22519 | A | 2 | 5 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| X69-218 | 11253 | EL-RAD MFG CO | A | H |
| 247AS-C0560-001 | 30003 | NAVAL AIR SYSTEMS COMMAND | A | A |
| 247AS-C0560-001 | 22519 | DATA DELAY DEVICES INC | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | X | D | 12/09/1 | P | 8543909000 | 0637 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| D | U | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | SMS | J | 0 | EA | 0 | 7 | 9B----- | N | |
| DS | SMS | J | 0 | EA | 0 | 7 | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 72D | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |